10Base-T1S Network Technology in SPE (Single Pair Ethernet)

Date: 29 May 2026
Aurthor: Owen Zhang (FAE Manager)

The essential difference between 10Base-T1S Ethernet and traditional Ethernet is the use of PHY layer technology incorporating PLCA (Physical Layer Collision Avoidance), which operates as a half-duplex communication system.

Principles of PLCA Technology

  • It is essentially a sequential polling communication mechanism that assigns a unique ID to every node in the network and polls them in order according to their ID.
  • It specifies a fixed time for each node to send or receive data or commands.
  • The entire communication process is initiated and coordinated by a PLCA coordinator (usually node ID 0), which sends a Beacon signal to mark the start of a communication cycle.

Core Characteristics

  •   Communication timing and latency are deterministic; prior to the initiation of a communication cycle, all timing and latency across network nodes can be accurately predicted and calculated.
  • The communication cycle consists of: Beacon + Data Frames for each node + Silent period.
  • Beacon and Silent durations are fixed, while frame duration is determined by the length of the data carried within the frame (data length ranges from 64 Bytes to 1536 Bytes).
  • Therefore, while the time and latency of a single T1S communication cycle vary depending on the number of nodes and data volume, the overall cycle is deterministic and predictable.
     

Application Highlights

  • Topology: Nodes are daisy-chained via a single twisted-pair cable before connecting to a switch, significantly reducing the wiring complexity of star network topologies.
  • Capacity/Range: Supports up to 50 nodes, with a maximum distance of 2m between nodes; the total network cable length cannot exceed 100m, categorizing it as short-range communication.
  • Compatibility: Can be seamlessly integrated into traditional Ethernet via switches.
     

MCHP 5 Categories of T1-S Chips

Categories of T1-S ChipMicrochip Part no.
PHYLAN8670 / LAN8671 / LAN8672
MAC+PHYLAN8650 / LAN8651
EndpointLAN8660 / LAN8661 / LAN8662
PMD TransceiverLAN8679 / LAN8680
MCU with Integrated T1SPIC32CM系列 / dsPIC33AK系列

Comparison with Other Network Buses

T1S vs. RS-485 / CAN / Modbus:

  • T1S can avoid network collisions at the physical layer entirely.
  • T1S supports precise 1588 time synchronization protocols and PoE (Power over Ethernet), which other buses cannot do.
  • T1S is seamlessly compatible with traditional IT networks without the need for a gateway, making it highly suitable for automotive or industrial data-to-cloud requirements.

T1S vs. EtherCAT:

  • All nodes on a T1S network bus are equal; unlike EtherCAT, there is no master-slave relationship.
  • T1S does not require a gateway for seamless compatibility with traditional Ethernet, whereas EtherCAT requires gateway support.
  • T1S solutions are more cost-effective than EtherCAT, and the chips are significantly smaller in both cost and volume.

 

Applications

  • Automotive: Interconnection of various internal systems such as motors, lighting systems, audio systems, power trains, and domain controllers.

  • Industrial Automation: Interconnection and cloud connectivity for sensors, actuators, alarm systems, HVAC, and refrigeration equipment.

  • Systems: Elevator systems, robotics, and energy storage system management/monitoring in smart energy.

  • Data Centers: Management and monitoring.

  • Medical: Interconnection and monitoring/management of medical equipment in hospital wards, operating rooms, and laboratories.